Menü überspringen

EIB 192

Request

Documentation

undefinedProduct Information

Specifications

EIB 192

EIB 192 F

EIB 192 M

Input

Incremental signals

1 VPP

Reference mark

One or distance-coded1)

Input frequency

≤ 400 kHz

Electrical connection

M23 connector, 12-pin

Cable length

≤ 6 m

Output

Absolute position values

EnDat 2.2

Fanuc Serial Interface

Mitsubishi High Speed
Serial Interface

Order designation

EnDat 22

Fanuc 02

Mit 02-4 / Mit 02-24)

Electrical connection

M12, 8-pin

M23, 17-pin

M23, 17-pin

Cable length

≤ 100 m2)

≤ 20 m3)

≤ 20 m3)

Interpolation

≤ 16 384-fold (depending on the encoder)

Power supply

5 V ± 5% measured at EIB

Current consumption

≤ 160 mA (without load, without encoder)

Operating temperature

Storage temperature

0 °C to 70 °C

–30 °C to 70 °C

Vibration 55 to 2000 Hz
Shock 11 ms

100 m/s2 (IEC 60 068-2-6)
300 m/s2 (IEC 60 068-2-27)

Degree of protection

IP 65

Weight

Approx. 0.3 kg

1) Note: For distance-coded reference marks, no direction reversals are permitted during referencing (scanning of two neighboring reference marks)

2) with HEIDENHAIN cable; supply voltage of 5 V ± 5% at the EIB must be maintained

3) with HEIDENHAIN cable; IEncoder ≤ 150 mA; greater cable lengths upon request

4) Mitsu01 upon request